A dining room at 25% humidity opens joints by itself
Beech moves 0.3% per 1% moisture change. Winter air in a heated room does the rest.
The band
35–60% RH is the band; below 30% in winter a dry frame opens at the joints A public area run at 25% in January is 10 points outside that band, and the timber responds whether the joint was cut well or badly.
The gaps appear at the seat rail first, because that is the shortest end grain run — winter drying and joint gaps has the seasonal pattern.
What is not the cause
Not the glue and not the joint. The failed joint moves under load; a dried joint shows an even gap the length of the shoulder and closes again in summer.
Frames that survive the swing are on hotel dining chairs, and the timber side is in case hardening and cupping.
The fix
The humidifier on the air handling unit, or a set point raised to 35%. Both are cheaper than a claim, and both are decisions the engineering team owns, not the furniture supplier.
This is the second section of the care guide, with moisture in a freshly sprayed part as the note on the factory end of the same number.
The rooms that run at 25% in winter are usually the ones on forced air, and the chairs in them are on contract dining chairs.