Seat count from floor area, before anyone draws a table
1.3–1.6 m² per cover is the band. Below 1.3 the room works on paper and fails on a Friday.
The band
1.6 m² per cover for a room with 1,200 mm routes and four-tops. 1.3 m² for a tight room with banquettes and no service route. Under 1.2 m² the room is a queue with tables in it.
The reason the lower number fails is in circulation and service routes.
How to apply it
Take the usable floor, subtract the service zone, divide by 1.5. That is the honest seat count. Then lay out to that number, not to the number the owner wants.
Rooms laid out to it hold their covers, and the furniture that fits is on hotel dining chairs.
Where the area goes
Banquettes and window two-tops are the two zones that beat the average. The room that is 40% banquette runs at 1.15 m² per cover and still walks.
This is in the design guide, with area per cover benchmarks as the note on the numbers by room type.
Floors that hold 1.5 m² per cover are the ones laid out around fixed seating, and the chairs that fill the rest are on hotel dining chairs.