The step-free route is the main route, drawn once
900 mm clear, no threshold, and it has to reach a table, not just the room.
The requirement
900 mm clear width from the entrance to a seated position, and 1,500 mm turning space at the table. The route is not a separate line on the plan; it is the main route used properly.
The clearances are tabulated in accessible clearances, and the width itself in circulation and service routes.
Where it breaks
The level change at a terrace door, a fixed banquette at the only wide point, a service station 850 mm off the wall. Three common ones, all fixable on paper.
Rooms that hold the route use shallow fixed seating on one wall — see banquette seating — and loose chairs elsewhere, on hotel dining chairs.
The test
Draw the route with a 900 mm shaded band from the door to a specific table. If the band has to pass through a chair, the chair moves.
This is in the design guide, with terrace threshold and level change as the note on the outdoor continuation.